G3 Starter Kit Pro
search
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro
  • G3 Starter Kit Pro

G3 Starter Kit Pro

€759.87

Starter kit that provides complete entry and exit control for a single door with two readers and support for Apple Touch Pass.

Quantity
delivery time unknown

G3 Starter Kit Pro

Starter kit that provides complete entry and exit control for a single door with two readers and support for Apple Touch Pass.

  • (1) Door hub
  • (1) G3 Pro Reader
  • (1) G3 Reader for door opening, or access for an additional door (second Hub required)
  • (2) Bag key rings
UA Hub Door
Mechanical
Dimensions 174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3")
Weight 363 g (12.8 oz)
Housing material Polycarbonate
Mounting material Polycarbonate
Hardware
Network interface (5) 10/100/1000 Base-T
Feeding method
  • PoE++
  • UL 294 Power-Limited Class 2 PSU
  • UL 60950-1/62368-1 LPS/PS2 PSU
Max. power consumption
  • Without PoE output: 30W
  • With PoE output: 50W
PoE input 50V DC, 1A
PoE output PoE passthrough, (4) PoE, 50V DC, total 20W
LEDs White/Blue
Knob (1) Factory reset
Digital input Request to Exit/Request to Enter/Remote Unlock/Door Position Sensor
Dry exit
  • Relay Lock: 30V DC, 1A
  • Aux: 30V DC, 1A
Powered output relay
  • Lock: 12V DC, 1A
  • Aux: 12V DC, 0.33A
  • 12V DC, 0.33A
Operating environment For indoor use only
Ambient temperature 0 to 40° C (32 to 104° F)
Relative humidity 5 to 95% non-condensing
UL 294 level
  • Destructive Attack: Level I
  • Line protection: level I
  • Sustainability: Level I
  • Standby power: level I
UL 294 Statement
  • Conformance to IEEE 802.3 (at or af) specifications has not been verified as part of UL 294.
  • The equipment is intended to comply with Section 70 of the National Electrical Code, ANSI/NFPA, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 Rank Rank Assignment: 1
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Wiring Information
Wire gauge (AWG) requirements Total length to device Output load current at 12V DC
100mA 250mA 500mA 1A
6.1 m (20 ft) 22 22 18
15.2 m (50 ft) 22 22 18
30.5 m (100 ft) 22 18 18
UACC Cable Door Lock Relay (18 AWG) is recommended.
PoE Cabling Requirements The minimum gauge of conductors that may be connected between the PSE or current injector and the PD is 24 AWG (0.21 mm2) for horizontal or riser cables.
UA-G3
Mechanical
Dimensions 93 x 40 x 36.5 mm (3.7 x 1.6 x 1.4")
Weight 82 g (2.9 oz)
Housing material Polycarbonate, glass
Mounting material Aluminum alloy
Assembly In wall, hallway cupboard
Weather resistance IP55
Hardware
Network interface (1) 10/100 MbE RJ45 port
Connectivity
  • BLE 4.1
  • NFC
Feeding method
  • PoE
  • UL 294 Class 2 Limited Power PSU
  • UL 60950-1/62368-1 LPS/PS2 PSU
Supported voltage range 48V DC
Max. power consumption 5W
ESD/EMP protection Air: ±15kV, contact: ±8kV
Sensors Proximity sensor
Loudspeaker (1) 8 ohm, 0.7W
LEDs (1) Status light
Knob (1) Factory reset
NFC frequency 13.56 MHz
NFC reading range < 30 mm
NFC technology
  • ISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340)
  • MIFARE Classic / MIFARE DESFIRE
  • Sony FeliCa™ (ID only)
  • NFC Forum tags T1T, T2T, T3T, T4T and T5T
  • ECP 2.0
Operating environment Outdoor use
Ambient temperature -30 to 45° C (-22 to 113° F)
Relative humidity 5 to 90% non-condensing
Software information The software version of a product can be checked at https://unifi.ui.com
UL 294 level
  • Destructive Attack: Level I
  • Line protection: level I
  • Endurance: Level I
  • Standby power: level I
UL 294 statement
  • Compliance with the IEEE 802.3 specifications has not been verified as part of UL 294.
  • The equipment is intended to comply with Section 70 of the National Electrical Code, ANSI/NFPA, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
PoE Cabling Requirements
  • Cable 5e cabling is the minimum recommended performance category. The performance category used must match the transmission speed required at the installation location.
  • The minimum gauge of conductors that may be connected between the PSE or current injector and the PD is 26 AWG (0.13 mm2) for patch cables; 24 AWG (0.21 mm2) for horizontal or riser cables.
CAN/ULC-60839-11-1 Grade Number assignment: I
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
LED
System
  • Steady Blue: Adopted/Device is ready
  • Solid white: Awaiting adoption
  • Flashing white/blue: Firmware is being upgraded
  • Flashing red: Emergency lock
  • Solid orange: Display over or under operating temperature
UA-G3
Mechanical
Dimensions 93 x 40 x 36.5 mm (3.7 x 1.6 x 1.4")
Weight 82 g (2.9 oz)
Housing material Polycarbonate, glass
Mounting material Aluminum alloy
Assembly In wall, hallway cupboard
Weather resistance IP55
Hardware
Network interface (1) 10/100 MbE RJ45 port
Connectivity
  • BLE 4.1
  • NFC
Feeding method
  • PoE
  • UL 294 Class 2 Limited Power PSU
  • UL 60950-1/62368-1 LPS/PS2 PSU
Supported voltage range 48V DC
Max. power consumption 5W
ESD/EMP protection Air: ±15kV, contact: ±8kV
Sensors Proximity sensor
Loudspeaker (1) 8 ohm, 0.7W
LEDs (1) Status light
Knob (1) Factory reset
NFC frequency 13.56 MHz
NFC reading range < 30 mm
NFC technology
  • ISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340)
  • MIFARE Classic / MIFARE DESFIRE
  • Sony FeliCa™ (ID only)
  • NFC Forum tags T1T, T2T, T3T, T4T and T5T
  • ECP 2.0
Operating environment Outdoor use
Ambient temperature -30 to 45° C (-22 to 113° F)
Relative humidity 5 to 90% non-condensing
Software information The software version of a product can be checked at https://unifi.ui.com
UL 294 level
  • Destructive Attack: Level I
  • Line protection: level I
  • Endurance: Level I
  • Standby power: level I
UL 294 statement
  • Compliance with the IEEE 802.3 specifications has not been verified as part of UL 294.
  • The equipment is intended to comply with Section 70 of the National Electrical Code, ANSI/NFPA, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
PoE Cabling Requirements
  • Cable 5e cabling is the minimum recommended performance category. The performance category used must match the transmission speed required at the installation location.
  • The minimum gauge of conductors that may be connected between the PSE or current injector and the PD is 26 AWG (0.13 mm2) for patch cables; 24 AWG (0.21 mm2) for horizontal or riser cables.
CAN/ULC-60839-11-1 Grade Number assignment: I
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
UA-Pocket
Mechanical
Dimensions 84 x 39 x 7.4 mm (3.3 x 1.5 x 0.3")
Weight 16 g (0.56 oz)
Housing material Polycarbonate, stainless steel, silicone rubber
Weather resistance IP54
Hardware
NFC frequency 13.56 MHz
NFC technology
  • ISO/IEC 14443 type A
  • MIFARE DESFire EV3 4K
  • UniFi Access proprietary security protocol
Ambient temperature -10 to 45° C (14 to 113° F)
Relative humidity 10 to 90% non-condensing
Certification CE
005-01538

Specific References

  • Name : 14 day return policy - 2 year warranty
  • Description

    Your RMA request has been submitted. We will pick up the item you wish to return within 6 days. We hope you understand that we only accept items for return if they have not been used or tampered with. Original packaging and accessories also need to be returned along with item.

  • Click here to get more details